Below you will find an extract of the different error codes you might find in the Cryptlex licensing services.
The message comment is written just above the error code for each entry in the list.
 
   /*
        CODE: LA_OK
        MESSAGE: Success code.
    */
    LA_OK = 0,

    /*
        CODE: LA_FAIL
        MESSAGE: Failure code.
    */
    LA_FAIL = 1,

    /*
        CODE: LA_EXPIRED
        MESSAGE: The license has expired or system time has been tampered
        with. Ensure your date and time settings are correct.
    */
    LA_EXPIRED = 20,

    /*
        CODE: LA_SUSPENDED
        MESSAGE: The license has been suspended.
    */
    LA_SUSPENDED = 21,

    /*
        CODE: LA_GRACE_PERIOD_OVER
        MESSAGE: The grace period for server sync is over.
    */
    LA_GRACE_PERIOD_OVER = 22,

    /*
        CODE: LA_TRIAL_EXPIRED
        MESSAGE: The trial has expired or system time has been tampered
        with. Ensure your date and time settings are correct.
    */
    LA_TRIAL_EXPIRED = 25,

    /*
        CODE: LA_LOCAL_TRIAL_EXPIRED
        MESSAGE: The local trial has expired or system time has been tampered
        with. Ensure your date and time settings are correct.
    */
    LA_LOCAL_TRIAL_EXPIRED = 26,

    /*
        CODE: LA_RELEASE_UPDATE_AVAILABLE
        MESSAGE: A new update is available for the product. This means a new release has
        been published for the product.
    */
    LA_RELEASE_UPDATE_AVAILABLE = 30,

    /*
        CODE: LA_RELEASE_NO_UPDATE_AVAILABLE
        MESSAGE: No new update is available for the product. The current version is latest.
    */
    LA_RELEASE_NO_UPDATE_AVAILABLE = 31,

    /*
        CODE: LA_E_FILE_PATH
        MESSAGE: Invalid file path.
    */
    LA_E_FILE_PATH = 40,

    /*
        CODE: LA_E_PRODUCT_FILE
        MESSAGE: Invalid or corrupted product file.
    */
    LA_E_PRODUCT_FILE = 41,

    /*
        CODE: LA_E_PRODUCT_DATA
        MESSAGE: Invalid product data.
    */
    LA_E_PRODUCT_DATA = 42,

    /*
        CODE: LA_E_PRODUCT_ID
        MESSAGE: The product id is incorrect.
    */
    LA_E_PRODUCT_ID = 43,

    /*
        CODE: LA_E_SYSTEM_PERMISSION
        MESSAGE: Insufficient system permissions. Occurs when LA_SYSTEM flag is used
        but application is not run with admin privileges.
    */
    LA_E_SYSTEM_PERMISSION = 44,

    /*
        CODE: LA_E_FILE_PERMISSION
        MESSAGE: No permission to write to file.
    */
    LA_E_FILE_PERMISSION = 45,

    /*
        CODE: LA_E_WMIC
        MESSAGE: Fingerprint couldn't be generated because Windows Management
        Instrumentation (WMI) service has been disabled. This error is specific
        to Windows only.
    */
    LA_E_WMIC = 46,

    /*
        CODE: LA_E_TIME
        MESSAGE: The difference between the network time and the system time is
        more than allowed clock offset.
    */
    LA_E_TIME = 47,

    /*
        CODE: LA_E_INET
        MESSAGE: Failed to connect to the server due to network error.
    */
    LA_E_INET = 48,

    /*
        CODE: LA_E_NET_PROXY
        MESSAGE: Invalid network proxy.
    */
    LA_E_NET_PROXY = 49,

    /*
        CODE: LA_E_HOST_URL
        MESSAGE: Invalid Cryptlex host url.
    */
    LA_E_HOST_URL = 50,

    /*
        CODE: LA_E_BUFFER_SIZE
        MESSAGE: The buffer size was smaller than required.
    */
    LA_E_BUFFER_SIZE = 51,

    /*
        CODE: LA_E_APP_VERSION_LENGTH
        MESSAGE: App version length is more than 256 characters.
    */
    LA_E_APP_VERSION_LENGTH = 52,

    /*
        CODE: LA_E_REVOKED
        MESSAGE: The license has been revoked.
    */
    LA_E_REVOKED = 53,

    /*
        CODE: LA_E_LICENSE_KEY
        MESSAGE: Invalid license key.
    */
    LA_E_LICENSE_KEY = 54,

    /*
        CODE: LA_E_LICENSE_TYPE
        MESSAGE: Invalid license type. Make sure floating license
        is not being used.
    */
    LA_E_LICENSE_TYPE = 55,

    /*
        CODE: LA_E_OFFLINE_RESPONSE_FILE
        MESSAGE: Invalid offline activation response file.
    */
    LA_E_OFFLINE_RESPONSE_FILE = 56,

    /*
        CODE: LA_E_OFFLINE_RESPONSE_FILE_EXPIRED
        MESSAGE: The offline activation response has expired.
    */
    LA_E_OFFLINE_RESPONSE_FILE_EXPIRED = 57,

    /*
        CODE: LA_E_ACTIVATION_LIMIT
        MESSAGE: The license has reached it's allowed activations limit.
    */
    LA_E_ACTIVATION_LIMIT = 58,

    /*
        CODE: LA_E_ACTIVATION_NOT_FOUND
        MESSAGE: The license activation was deleted on the server.
    */
    LA_E_ACTIVATION_NOT_FOUND = 59,

    /*
        CODE: LA_E_DEACTIVATION_LIMIT
        MESSAGE: The license has reached it's allowed deactivations limit.
    */
    LA_E_DEACTIVATION_LIMIT = 60,

    /*
        CODE: LA_E_TRIAL_NOT_ALLOWED
        MESSAGE: Trial not allowed for the product.
    */
    LA_E_TRIAL_NOT_ALLOWED = 61,

    /*
        CODE: LA_E_TRIAL_ACTIVATION_LIMIT
        MESSAGE: Your account has reached it's trial activations limit.
    */
    LA_E_TRIAL_ACTIVATION_LIMIT = 62,

    /*
        CODE: LA_E_MACHINE_FINGERPRINT
        MESSAGE: Machine fingerprint has changed since activation.
    */
    LA_E_MACHINE_FINGERPRINT = 63,

    /*
        CODE: LA_E_METADATA_KEY_LENGTH
        MESSAGE: Metadata key length is more than 256 characters.
    */
    LA_E_METADATA_KEY_LENGTH = 64,

    /*
        CODE: LA_E_METADATA_VALUE_LENGTH
        MESSAGE: Metadata value length is more than 256 characters.
    */
    LA_E_METADATA_VALUE_LENGTH = 65,

    /*
        CODE: LA_E_ACTIVATION_METADATA_LIMIT
        MESSAGE: The license has reached it's metadata fields limit.
    */
    LA_E_ACTIVATION_METADATA_LIMIT = 66,

    /*
        CODE: LA_E_TRIAL_ACTIVATION_METADATA_LIMIT
        MESSAGE: The trial has reached it's metadata fields limit.
    */
    LA_E_TRIAL_ACTIVATION_METADATA_LIMIT = 67,

    /*
        CODE: LA_E_METADATA_KEY_NOT_FOUND
        MESSAGE: The metadata key does not exist.
    */
    LA_E_METADATA_KEY_NOT_FOUND = 68,

    /*
        CODE: LA_E_TIME_MODIFIED
        MESSAGE: The system time has been tampered (backdated).
    */
    LA_E_TIME_MODIFIED = 69,

    /*
        CODE: LA_E_RELEASE_VERSION_FORMAT
        MESSAGE: Invalid version format.
    */
    LA_E_RELEASE_VERSION_FORMAT = 70,

    /*
        CODE: LA_E_AUTHENTICATION_FAILED
        MESSAGE: Incorrect email or password.
    */
    LA_E_AUTHENTICATION_FAILED = 71,

    /*
        CODE: LA_E_METER_ATTRIBUTE_NOT_FOUND
        MESSAGE: The meter attribute does not exist.
    */
    LA_E_METER_ATTRIBUTE_NOT_FOUND = 72,

    /*
        CODE: LA_E_METER_ATTRIBUTE_USES_LIMIT_REACHED
        MESSAGE: The meter attribute has reached it's usage limit.
    */
    LA_E_METER_ATTRIBUTE_USES_LIMIT_REACHED = 73,

    /*
        CODE: LA_E_CUSTOM_FINGERPRINT_LENGTH
        MESSAGE: Custom device fingerprint length is less than 64 characters
        or more than 256 characters.
    */
    LA_E_CUSTOM_FINGERPRINT_LENGTH = 74,

    /*
        CODE: LA_E_PRODUCT_VERSION_NOT_LINKED
        MESSAGE: No product version is linked with the license.
    */
    LA_E_PRODUCT_VERSION_NOT_LINKED = 75,

    /*
        CODE: LA_E_FEATURE_FLAG_NOT_FOUND
        MESSAGE: The product version feature flag does not exist.
    */
    LA_E_FEATURE_FLAG_NOT_FOUND = 76,

    /*
        CODE: LA_E_RELEASE_VERSION_NOT_ALLOWED
        MESSAGE: The release version is not allowed.
    */
    LA_E_RELEASE_VERSION_NOT_ALLOWED = 77,

    /*
        CODE: LA_E_VM
        MESSAGE: Application is being run inside a virtual machine / hypervisor,
        and activation has been disallowed in the VM.
    */
    LA_E_VM = 80,

    /*
        CODE: LA_E_COUNTRY
        MESSAGE: Country is not allowed.
    */
    LA_E_COUNTRY = 81,

    /*
        CODE: LA_E_IP
        MESSAGE: IP address is not allowed.
    */
    LA_E_IP = 82,

    /*
        CODE: LA_E_CONTAINER
        MESSAGE: Application is being run inside a container and
        activation has been disallowed in the container.
    */
    LA_E_CONTAINER = 83,

    /*
        CODE: LA_E_RATE_LIMIT
        MESSAGE: Rate limit for API has reached, try again later.
    */
    LA_E_RATE_LIMIT = 90,

    /*
        CODE: LA_E_SERVER
        MESSAGE: Server error.
    */
    LA_E_SERVER = 91,

    /*
        CODE: LA_E_CLIENT
        MESSAGE: Client error.
    */
    LA_E_CLIENT = 92